CodeDescriptionRecovery
PLPower too lowFirst 5 times: recover after 30 seconds; afterwards: recover after 30 minutes; resets after 1 minute of normal operation
P50Voltage too lowRecovers immediately once voltage returns to normal
P51Voltage too highNot specified
P60Over-temperature protection (temperature > 100°C)Recovers immediately when temperature drops below 60°C
P49Software overcurrentFirst 2 times: recover after 2 seconds; afterwards: no auto recovery, manual reset required
P0Hardware overcurrentNot specified
E8Current sampling faultPress ON/OFF to clear
P44Start failureRecovers after 3 seconds
P46Stall protectionRecovers after 2 seconds
P43Phase loss errorRecovers after 2 seconds
P48Dry-run protectionFirst 5 times: recover after 30 seconds; afterwards: recover after 30 minutes; resets after 1 minute of normal operation